Oil leaks from swivel
1. Swivel is loose
2. O-ring is worn or damaged
1. Tighten the swivel (part# 1-1)
2. Replace the o-ring (part# 1-14)
Oil drips from nozzle
Nozzle is damaged or obstructed
Inspect the nozzle for damage or
obstructions, and replace if damaged
Valve leaks
O-rings or valve seat are worn or
damaged
Replace the o-rings (part# 1-5) and/or
the valve seat (part# 1-10)
Leakage from meter
O-ring damaged
5. 1. Get the meter off from the dispense
system
6. 2. Take off the Rubber Protector (part#
3-4) and Front Label (part# 3-6)
7. 3. Remove four the socket head cap
screws (part# 3-8) on the cover of
the meter
8. 4. Remove eight the hex bolts (part#
3-18) on the bottom of the meter
9. 5. Take off the seat( part# 3-10)
10. 6. Check the o-ring (part# 3-1), replacing
the o-ring if it is damaged
11. 7. After replacing the o-ring, assemble
the meter and fix it back to the
dispense system
No display
Battery out of power
Replace the battery
Wrong reading
Wrong correction factor
Follow “CALIBRATION PROCEDURE”