Product Manual
Page 4 of 9
the entire system is clean, and close the valve.
. If there are several dispensing points, you need to drain the oil at each point, one by one, starting with the
furthest one from the pump, and ending with the nearest one to the pump.
Fig. 2 Oil Control Valve
How to adjust the angle of the nozzle: Loosen the #4 swivel nut, turn the nozzle to the desired position and
tighten the nut.
NOTE: Use oil resistant pipe sealant or Teflon® Tape on all fitting threads.
(1) Installing a new oil control valve
①. When installing a new control valve, first apply appropriate thread sealant around the male thread of oil
supplying system, then connect the male thread into the female thread of oil inlet of the control valve, and
fix them together.
②. Turn on all check valves of oil system.
③. Press the trigger to drain enough oil to make sure the oil system is completely cleaned. See “OPERATION
INSTRUCTIONS” section for the control valve operation.
④. Repeat steps ① to ③ for other oil control valves to be installed at each dispensing point in the system.
NOTE: To ensure the meter accuracy, purge all air out from the fluid lines and control valve before using them.
(2) Replacing oil control valve
①. Disconnect and take the oil control valve off the system.
②. Follow the steps ① to ④ in “(1) Installing the new oil control valve" section above.
OPERATION INSTRUCTIONS
WARNING:
Never operate the meter with the plastic cover removed. The cover protects the meter from damage
due to impact. Meters are sealed in the factory to keep moisture and dirt away.
Flush the lines before you install this equipment in the system to prevent line contamination, or it can
cause equipment malfunction or damaged.
To reduce the risk of a serious bodily injury, including fluid injection, never exceed the maximum working
pressure of the control valve you are using or of the lowest rated component in your system.
1. PRESSURE RELIEF PROCEDURE
WARNING: Skin injection hazard: The equipment stays pressurized until pressure is manually relieved.
To reduce the risk of serious injury from pressurized fluid, fluid from the valve or splashing fluid, follow this
procedure whenever you:
Are instructed to relieve pressure
Check, clean or service any system equipment
Install or clean dispensing devices
(1) Pressure relief procedure
①. Turn off the power supply to the pump.
②. Hold a metal part of the control valve firmly to a grounded metal waste container and point the valve
outlet toward the waste container, then trigger the control valve to relieve the fluid pressure.