Product Manual

Page 4 of 9
DAILY USE
The meter turns on automatically when fluid flow starts and turns off automatically shortly after flow stops to
conserve power. It can also be turned on manually by pressing and releasing the MENU/ RESET button.
1. Make sure there is no air in the system by starting the flow until it runs steadily. Then, stop the flow using
a valve or nozzle.
2. If desired, press the RESET key to zero the meter’s Present Total. When zeros appear, release the
button.
3. Meter an exact known volume into an accurate container. For best results, meter with one continuous full
stream.
4. Check the readout. If the amount metered is accurate, field calibration is not necessary. If not, refer to the
Calibration Section for further instructions.
5. Begin dispensing.
OPERATIONAL FUNCTIONS
RESETTING THE PRESENT TOTAL (See Fig. 2)
When the meter is on standby, press the RESET key.
The display will show all the segments.
Next, the meter will reset the present total to 0.00.
RESETTING THE RESETTABLE TOTAL (See Fig. 3)
When the meter is on standby, press and hold the RESET key for 2 seconds to reset the resettable total.