Product Manual

Page 3 of 8
The “LCD” of the meter features two numerical registers and various indications displayed to the users as
below:
INDICATIONS
Partial register (5 figures with moving comma from 0.1 to 99999)
Indicate the volume dispensed since the reset button was last pressed.
Indication of battery charge
Indication of calibration mode
Indication of resetting present total to Zero
Total register
Indication of flow rate mode
Indication of unit of measurement of partial: L= Liters
GAL = Gallons
PT = Pints
QT = Quarts
3. OPERATIONAL BUTTONS
The turbine digital meter features two buttons (MENU and RESET) which individually perform two main
functions and other secondary functions together.
The main functions performed are:
For the RESET key, resetting the partial Register and reset table total (reset total)
For the MENU key, entering the instrument calibration mode.
Used together, the two keys permit entering configuration mode.
4. BATTERY REPLACEMENT
When replacing the battery, please open the cover, remove the plug, and replace the battery. Replace cover
before operation.
INSTALLATION AND DAILY USE
This nozzle is designed to dispensing diesel fuel under 0.5~3.5bar/7~50psi pressure system.
1 Connect the nozzle directly with the delivery hose. Please be ensured the thread is
sealed.
2 Turn on the dispenser, open the trigger of nozzle to start dispensing. For first time using,
it is necessary to turn the trigger on and off 2-3 times to discharge the air inside.
3 After dispensing, turn off the nozzle and take back to nozzle holder.
OPERATIONAL FUNCTIONS
RESETTING THE PRESENT TOTAL (See Fig. 2)
When the meter is on standby, press the RESET key.
The display will show all the segments.
Fig. 1
Fig. 2