Product Manual

Page 16 of 25
After Each Use
WARNING
Store idle equipment. When not in use, tools and equipment should be stored in a dry location to
inhibit rust.
Maintenance
WARNING
Provide a clean work surface to protect sensitive internal moving parts from contamination from
dirt and foreign matter during service disassembly and reassembly.
Keep good records of service activity and include pump in preventive maintenance program.
Before disassembling, empty captured material in the outlet manifold by turning the pump upside
down to drain material from the pump.
Troubleshooting
Possible Cause
Corrective Action
Product discharged from exhaust outlet.
Check for diaphragm rupture
Check tightness of diaphragm
Air bubbles in product discharge.
Check connections of suction plumbing
Check O-rings between intake manifold
and fluid caps
Check tightness of diaphragm nut
Low output volume, erratic flow, or no flow.
Check air supply
Check for plugged outlet hose
Check for kinked (restrictive) or collapsed
inlet material hose
Check if there is leak in the connection.
Connections must be air tight
Inspect the pump for solid objects logged
in the diaphragm chamber or the seat area