Product Manual

Page 15 of 23
2. Open the manual tip.
3. Squeeze control handle trigger. When the required amount of product has been dispensed, release
the trigger to stop delivery. Close the manual tip.
Pressure Relief Procedure
To reduce the risk of serious bodily injury, including fluid injection, splashing in the eyes or on the skin,
or injury from moving parts, please always follow this procedure whenever you shut off the pump, when
check or service any part of the spray/dispensing system, when install, clean or change spray
tips/nozzles, and whenever you stop spraying/dispensing.
Shut off the air to the pump.
Point the outlet of grease gun to container and trigger the grease gun to relieve pressure.
Grease Pump Control Valve Operation:
WARNING
Never point the dispenser at people or animals.
Connect the control handle to the lubricant supply line (1/4 BSP or 1/4 NPT male thread required).
Open the manual tip.
Squeeze control handle trigger. When the required amount of product has been dispensed,
release the trigger to stop delivery. Close the manual tip.
After Each Use
WARNING
When not in use, disconnect the air supply air to the pump.
Always disconnect the air supply after use so that oil can't leak out in case one of the pump's
components should break.
Disconnect air hose and relieve air pressure before servicing.
Always dispose of oil and other liquids according to local waste authority guidelines.
Let in 50 grams of Vaseline oil or other lubricator from the air inlet hole.
Turn on the pump for several minutes until moving parts are fully lubricated. Do this weekly.
For the pumps that are attached with compressed air treatment equipment, empty the water
retained in the reservoir of the filter-purger frequently.
For the pumps that are attached with a lubricator, pay close attention to the lubricator's grease
level and refill with NLGL-2 conditions when necessary.
Maintenance
WARNING
Disconnect air hose and relieve air pressure before servicing.