Manual

E-M-PF4-V1_00
Rotronic AG
Bassersdorf, Switzerland
Document Code Unit
PF4 Differential Pressure Transmitter:
Instruction Manual
Instruction Manual
Document Type
Page
51 of 54
Document Title
© 2014; Rotronic AG E-M-PF4-V1_00
Configurable Analog Outputs
Output 1 Can be assigned to every parameter
Default parameter Differential pressure
Default range Per order code
Output 2 Can be assigned to every parameter
Default parameter Relative humidity / Temperature
Default range Per order code
Output 1 and output 2
Signal type
0…20 mA
4…20 mA
0…1 V
0…5 V
0…10 V
(user-configurable)
Accuracy analog output
±10 mV (voltage output)
±20 µA (current output)
User-configurable range limits -9,999...+99,999 units
Refresh interval 1 s
Short circuit tolerant Yes
Max. load 500 (current output)
Min. load resistance 1000 (voltage output)
Digital Interface
Interface type Ethernet, wired
Service Connector
Interface type UART (TTL Level)
Max. length of service cable 5 m (16.4 ft)