11 Specifications
Power supply AC Adapter 12 VDC regulated,
100 or 300 mA
1)
DC(+) Tip
Operating limits at electronics 0…99 %RH (non condensing)
-10...55°C (14...131°F)
Measured parameters
2)
relative humidity indication range 0.0…100.0 %RH
temperature
indication range
-99.9…999.9 °C or °F
barometric pressure
3)
indication range
0.000…9999 hPa / PSI / In Hg
Calculated parameters
2) 4)
dew / frost point
5)
indication range -99.9…999.9 °C / °F
wet bulb temperature
6)
indication range 0.0…100.0 °C / 32.0…212.0 °F
enthalpy
6)
indication range -99.9…9999 J/g or BTU/lb
vapor concentration indication range 0.000…9999 g/m3 or gr/cuft
specific Humidity
6)
indication range 0.000…9999 g/kg or gr/lb
mixing ratio
6)
indication range 0.000…9999 g/kg or gr/lb
vapor concentration at saturation indication range 0.000…9999 g/m3 or gr/cuft
part. pressure of water vapor indication range 0.000…9999 hPa / PSI / In Hg
sat. pressure of water vapor indication range 0.000…9999 hPa / PSI / In Hg
Number of probe inputs HygroLab 1 2
HygroLab 2+3 4
Probe type
7)
All models ROTRONIC HygroClip digital probe
All models ROTRONIC analog probe
8)
HygroLab 2+3 Third-party analog probe
8)
A/D resolution (analog probes) HygroLab 1+2 10-bit
A/D resolution (analog probes) HygroLab 3 12-bit
Display Alphanumerical LC display
Serial output (except HygroLab 1) RS 232 / RS485
9)
Optional Ethernet interface HygroLab 2+3 TCP/IP
Housing material Aluminum
Housing dimensions 220 x 170 x 55 mm (8.66 x 6.69 x 2.16”)
Weight 1.0 kg (2.2 lb)
1) HygroLab with optional Ethernet module requires : AC Adapter 12 VDC, 300 mA
2) Specify engineering units when ordering (can be changed by user with the optional HW4 software). See
separate probe specifications regarding the different range limits
3) Not available with HygroLab 1
4) Not available with HygroLab 1. The accuracy of the computed parameter is limited by the accuracy of the
measured parameters on which it is based
5) The standard factory setting is frost point for values below freezing. This setting can be changed to dew
point with the optional HW4 software
6) A fixed pressure value is used for the computations of this parameter. The fixed pressure value can be
changed by the user either from the keypad or with the optional HW4 software. The HygroLab 2 and 3 can
also be configured with the HW4 software to accept the input from a pressure probe (variable pressure
value)