With ‘Polling’ checked, the program will automatically read and display the unit’s
current settings.
The “System Address” box displays the system address for the Unit. This
number is unique to each system.
The “Unit Number” box displays the number for the Unit within the system.
Remotes will be 1 through 8 and the Mini Controller will be Unit 0.
The “Frequency (MHz)” box displays the transmitter and receiver frequencies, in
Mega Hertz, for the Unit.
The “Fire Count” box displays the number of times the Remote has been fired.
The “Serial Number” box displays the Manufacturer’s serial number for the Unit.
The “Date of Manufacture” box displays when the Unit was manufactured.
The “Type” box displays the Manufacture’s type code for the Unit.
Boxes that are displayed in gray are not programmable and are for information
purposes only.
The “Firmware Version” box displays the version of firmware that is programmed
into the Unit.