User's Manual

Table Of Contents
Battery SN 0001
Battery DOM 02/03/2011
The next message displayed shows the System Number or Address (0000000001) and
the Unit that the RSTI is assigned to.
The next message dis shows the assigned Frequency and the Message Number.
del) date of
manufacture (DOM), firmware version (Ver).
unt.
ins 5
Address 0000000001
Unit 3
played
The next messages displayed are the serial number (S/N), unit Type (Mo
Frequency 174 MHz
Message Number 010000
S
D
/N 00101 Type 1678-3
OM 06/29/2010 Ver 1.0
The next message displayed is the firmware Checksum and the Fire Co
Checksum 4624
Fire Count 87
Next the RSTI begins the Arm/Fire Test. The Test Box Arms the RSTI and beg
second countdown.
RSTI Arm/Fire Test
05
At the end of the countdown, the RSTI fires resulting in the formation of a spark at the
tip. The firing voltage and pass level is shown.
1678 RFD OPERATION MANUAL {DRAFT}
59