User's Manual

Table Of Contents
The next message displayed is the Mini Controller’s serial number (S/N), unit Type
(Model) date of manufacture (DOM), firmware version (Ver).
Next the Mini Controller begins a Battery Test.
The Battery Test places a load on the battery and a countdown timer is started. At the
end of the test, the loaded battery voltage is displayed along with the test limit of (7.00).
After testing is complete, the following message is displayed.
9.2.3. Testing the Electric Remote
WARNING
S/N 00101 Type 1678-6
r 1.0 DOM 06/29/2010 Ve
The next message displayed is the firmware Checksum and the Fire Count.
Checksum 4C42
Fire Count 87
Battery Test – Standby
30
Loaded Battery 7.24
<Low Battery = 7.00>
Testing Completed
Do not touch the firing terminals of the Remote units while testing. A
potentially lethal voltage is present during the Fire test.
To test an Electric Remote, plug the Test Box probe into the top connector on the
Electric Remote. The Electric Remote turns on with the yellow light fast blinking and the
green light on. The Test Box will display the following message.
1678 RFD OPERATION MANUAL {DRAFT}
55