3.4. TIMING
Mini Controller Unit ARM time: 1/2 ± 0.1 Seconds
Electric Remote Unit ARM time: 7 ± 0.5 Seconds
RSTI Unit ARM time: 4 ± 0.5 Seconds
Mini Controller Unit Arm Time
Period:
1 – 60 Minutes (20 Minute Default) **
Remote Unit Arm Tim Period: 1 – 60 Minutes (20 Minute Default) **
Mini Controller Unit DISARM time: 3 ± 0.1 Seconds
Remote Unit DISARM time: 3 ± 0.1 Seconds
Mini Controller Unit FIRE time: 1 ± 0.1 Seconds
Remote Unit FIRE time:* 20 Milliseconds
*This is the delay after the Remote Unit receives the command signal from the Mini
Controller Unit to Fire.
**The system’s Arm Time Period is factory set. Consult Rothenbuhler Engineering for
details.
3.5. DETONATE OUTPUT
The Remote Unit detonation output pulse is from a 2200 microfarad capacitor charged
to 50 volts.
Stored Energy Level: 2.8 Joule (typical), 1.8 Joule (minimum)
Pulse Voltage Level: 50 VDC (typical), 45 VDC (minimum)
Maximum Firing Resistance:* 28
*This includes firing cables, detonators, & detonator leg wires.
The Remote Shock Tube Initiator (RSTI)’s output pulse is from a 0.15 microfarad
capacitor charged to 2,500 volts.
Stored Energy Level: 0.470 Joule (typical), 0.350 Joule (minimum)