Disarm the Remote Unit: Depress the “DISARM” switch. The Mini
Controller Unit will transmit the Disarm command to selected Remote Units. Selected
Remote Units will internally discharge their firing capacitor. Selected Remote Units that
receive the Disarm command will become disarmed within 3 seconds of receiving the
command. The green DISARMED light for selected Remote Units will begin to flash on
the Mini Controller Unit display panel. The Mini Controller Unit will then request status
of selected Remote Units. If the Mini Controller Unit is within range of the selected
Remote Unit transmitter, the green DISARMED light for that Remote Unit will turn to
steady on the Mini Controller Unit display panel. If the Mini Controller Unit is out of
range of the selected Remote Unit transmitter, the green DISARMED light for that
Remote Unit will continue to flash on the Mini Controller Unit display panel. If the Fire
command is not sent within the Arm Time Period, the system will disarm automatically.
CAUTION Do not assume the Disarm command has been received by the Remote
Unit unless DISARMED status is confirmed with a steady DISARMED light for that
Remote Unit on the Mini Controller Unit display panel. If distance appears to be the
problem, move closer to the Remote Unit following standard procedures for this type of
situation. The “STATUS” and/or “DISARM” switches may be pressed repeatedly as the
Remote Unit is approached. Maintain a safe distance from the Remote Unit. Do not
approach the Remote Unit until DISARMED status is confirmed with a steady
DISARMED light for that Remote Unit on the Mini Controller Unit display panel. Under
no conditions should the “FIRE” switch be pressed as the Remote Unit is approached.
DO NOT bring the Mini Controller Unit closer than 100 feet (30 meters) to blasting caps,
wires connected to blasting caps, or other explosives.
Activate the Remote Unit Firing Circuit: Depress the “FIRE” switch for 1/2
second and the Mini Controller Unit will transmit the Fire command to selected Remote
Units. The Mini Controller Unit will only transmit the Fire command to selected Remote
Units whose status is Armed. The selected Remote Units will be placed in Fire Mode
and discharge the firing capacitor across the binding posts. The red ARMED light will
turn off and the green DISARMED light for each selected Remote Unit will begin to flash
on the Mini Controller Unit display panel. The Mini Controller Unit will then request
status from the selected Remote Units. If the Mini Controller Unit is within range of the
selected Remote Unit transmitter, the DISARMED green light for that Remote Unit will
turn to steady on the Mini Controller Unit display panel. If the Mini Controller Unit is out
of range of the selected Remote Unit transmitter, the green DISARMED light for that
Remote Unit will continue to flash on the Mini Controller Unit display panel.
Multistage Firing of Remote Units: Multistage firing provides the ability to
arm all four Remote Units at one time, and select any combination of the Remote Units
to fire at different intervals within the Arm Time Period. The procedure for multistage
firing is:
Depress “1” though “4” switches.
Depress “ARM” switch – all four Remote Units will arm.
1678 RFD OPERATION MANUAL {DRAFT}
9