User's Manual

Table Of Contents
2.3.2.
2.3.3.
2.3.4.
2.3.5.
2.3.6.
Power ON Self Test: Upon installing the antenna and pressing the “ON”
switch, a rigorous self test is initiated. If a failure of the self test occurs, it will not be
possible to activate the unit. The unit must be returned to the Manufacturer for service.
Do not attempt to use a failing unit.
Display Panel Light Dimmer Circuit: With the unit powered on, Repress
the ‘ON’ switch briefly to toggle the LED display light’s intensity between bright and dim.
When the unit is turned on, the last chosen intensity setting is restored.
Select Remote Units: Depress the Select Switches “1” through “4” to select
independently the Remote Units that will communicate with the Mini Controller Unit.
Any combination of the four Remote Units may be selected. The yellow SELECT light
on the switch indicates if the Remote Unit programmed for that switch is selected.
Press the switch again and the yellow SELECT light for that Remote Unit will be turned
off indicating the Remote Unit is not selected.
Request Remote Unit Status: Depress the “STATUS” switch to transmit a
status request signal to the selected Remote Units. The selected Remote Units will
transmit their current status to the Mini Controller Unit. If none of the Remote Units are
selected, the Mini Controller Unit will request status from all four Remote Units. Any
answering Remote Units will be selected automatically. If the Mini Controller Unit is
within range of the Remote Unit transmitter, the status of the selected Remote Unit will
be presented on the display panel with a steady light. If the Mini Controller Unit is out of
range of the Remote Unit transmitter, the status will be assumed from the last command
sent to that Remote Unit. In that case the assumed status of the Remote Unit will flash
on the display panel.
Arm the Remote Unit: Depress the “ARM” switch for 1/2 second and the
Mini Controller Unit will transmit the Arm command to the selected Remote Units. The
red ARMED light at the selected Remote Units will flash on the Mini Controller Unit
display panel until the firing capacitor charging time is completed. The Mini Controller
Unit then requests status of the selected Remote Units. If the Mini Controller Unit is
within range of the selected Remote Unit transmitter, the ARMED red light for that
Remote Unit will be on steady on the Mini Controller Unit display panel. If the Mini
Controller Unit is out of range of the selected Remote Unit transmitter, the red ARMED
light for that Remote Unit will continue to flash on the Mini Controller Unit display panel.
If the Fire command is not sent within the Arm Time Period, the system will disarm
automatically.
1678 RFD OPERATION MANUAL {DRAFT}