10.4. EXTENDED NON-USE
3 Position Charger: For optimal storage life, store units with their batteries discharged to
a low battery. Several full charge/discharge cycles may be necessary before the
battery’s capacity is restored to full. Units should be stored without the antennas
attached.
5 Position Charger Conditioner: For optimal battery health, use the Discharge (Store)
function to discharge the battery before storage. Use the Condition (Restore) function
prior to use. Units should be stored without the antennas attached.
Do not exceed the storage temperature guidelines below. Storage outside of this range
may reduce battery capacity and/or cause physical deterioration of battery components.
Storage Time Storage Temperature
<30 days -4 to 122°F (-20 to +50°C)
30 - 90 days -4 to 104°F (-20 to +40°C)
>90 days -4 to 86 °F (-20 to +30°C)