• Notes can be added to the log file by clicking the note card icon and typing the
note in the dialog box that appears. Multiple notes can be added as required.
• Connect the Test Box Probe to an Electric Remote Unit, RSTI, or Controller.
• If testing the Controller, place the unit in Program mode by turning the unit on
while holding the select switch for #3.
• The Test Box reads and displays the system information from the unit connected
both on the LCD display of the Test Box, and on the RFD HS Terminal Utility
window. The Electric Remote and RSTI will begin reading and displaying unit
parameters automatically and then will conduct an ARM/FIRE test. The
Controller displays unit parameters. All units then execute a loaded battery test
voltage test. The results are displayed as shown in the next window.