1678 RFD OPERATION MANUAL 61
Next the Electric Remote begins a Battery Test.
The Battery Test places a load on the battery and a countdown timer is started. At the
end of the test, the loaded battery voltage is displayed along with the test limit of (7.00).
After testing is complete, Electric Remote’s loaded battery voltage and firing voltage are
displayed.
9.1.4. Testing the RSTI
WARNING
Do not touch the firing terminals of the Remote units while testing. A
potentially lethal voltage is present during the Fire test.
To test an RSTI, install the firing tip on the top of the RSTI and plug the Test Box probe
into the top connector on the RSTI. The RSTI turns on with the yellow light fast blinking
and the green light on. The Test Box will display the following message.
Next the Test Box will display the Battery Charge Count as shown below. This is the
number of charge cycles the battery within the RSTI has experienced.
Battery Charge Count
83
RSTI Detected
Loaded Battery 7.24
<Low Battery = 7.00>
Battery Test – Standby
30
Battery Voltage 7.24
Firing Voltage 51.54