User's Manual
1678 RFD OPERATION MANUAL 58
The next message displayed shows the System Number or Address (0000000001) that
the Controller is assigned to and the Unit assigned to the Controller (Default is Unit 1).
The next message displayed shows the assigned Frequency.
The next message displayed is the Controller’s serial number (S/N), unit Type (Model)
date of manufacture (DOM), firmware version (Ver). The actual message will depend
on the model of Controller.
The next message displayed is the firmware Checksum and the Fire Count.
Next the Controller begins a Battery Test.
The Battery Test places a load on the battery and a countdown timer is started. At the
end of the test, the loaded battery voltage is displayed along with the test limit of (7.00).
Loaded Battery 7.24
<Low Battery = 7.00>
Battery Test – Standby
30
Checksum 4C42
Fire Count 87
S/N 00101 Type 1678-6
DOM 06/29/2010 Ver 1.0
Frequency 174 MHz
Address 0000000001
Unit 1