User's Manual
1678 RFD OPERATION MANUAL 48
• The Remote Unit battery is sufficiently charged to activate the firing circuit.
• A DISARM command should not be assumed.
5.5.4. Ensure the area is clear.
5.5.5. Turn the Controller on.
5.5.6. Press the “STATUS” switch. The Controller will request status from all
Remote Units. The red TX light will flash for approximately 5 seconds. The green
SAFE light on the Controller display panel will flash for all the Remote Units that the
Controller does not receive a status message from.
5.5.7. Select the Remote Units that are to be used in the shot by pressing the
corresponding numbered switches “1” through “4” or “8”. Press the numbered
switches one at a time.
System Safety Feature
Once armed, the Remote Units must be sent a Fire
command within the Arm Time Period. If the Remote Units do not receive a Fire
command within the Arm Time Period, they will automatically disarm. The firing
capacitor will be safely internally discharged, the binding posts will remain isolated from
the firing capacitor and the binding posts will remain shunted together.
5.5.8. To arm the selected Remote Units, press the “ARM” switch. The red
ARMED light next to each selected Remote Unit switch will flash for 5 seconds, and
then come on steady for two seconds. ARMED lights for selected Remote Units that
the Controller did not receive a status message from will begin to flash again. The
selected Remote Units are now assumed to be ARMED! For unconfirmed
communications, count to 5 from when the "ARM" switch is pressed and assume the
Remote Units are armed.
5.5.9. To fire the Remote Units, press the “FIRE” switch. The operator should get
an indication of shot initiation. The ARMED light will go out and the green SAFE light
for each selected Remote Unit will flash on the Controller display panel.
5.5.10. If not all the Remote Units were selected for the shot, repeat above steps to
initiate the remaining shots.
5.5.11. To disarm any Remote Units that have been armed, select Remote Units
and press the “DISARM” switch. All selected Remote Units will disarm in
approximately 3 seconds.