User's Manual
1678 RFD OPERATION MANUAL 23
2.10.4. LCD Display: The LCD displays information both from the Test Box itself
during its power on sequence, and while reading and testing a Controller, Mini
Controller, Electric Remote, or RSTI. The LCD’s backlighting will turn on while the unit
is active. The information that may be displayed on the LCD is listed below:
• Serial Number
• Date of Manufacture
• System Number
• Unit ID
• Frequency Assignments
• Firmware Checksum and Version
• Battery Temperature and Charge Cycle Count
• Fire Count
• Battery voltage of unit under test while the battery is being loaded down.
• Electric Remote Units and RSTIs under test are armed and fired. The firing
voltages are displayed.
2.10.5. Power Input Jack: The Test Box is powered from +12VDC from an AC
adapter. The AC adapter is capable of international use.
2.10.6. Serial Identification Label: This label provides information such as the
Model Number, Serial Number, System Number, Assigned Frequency, and
certification numbers.