User's Manual

1678 RFD OPERATION MANUAL 23
2.10.4. LCD Display: The LCD displays information both from the Test Box itself
during its power on sequence, and while reading and testing a Controller, Mini
Controller, Electric Remote, or RSTI. The LCD’s backlighting will turn on while the unit
is active. The information that may be displayed on the LCD is listed below:
Serial Number
Date of Manufacture
System Number
Unit ID
Frequency Assignments
Firmware Checksum and Version
Battery Temperature and Charge Cycle Count
Fire Count
Battery voltage of unit under test while the battery is being loaded down.
Electric Remote Units and RSTIs under test are armed and fired. The firing
voltages are displayed.
2.10.5. Power Input Jack: The Test Box is powered from +12VDC from an AC
adapter. The AC adapter is capable of international use.
2.10.6. Serial Identification Label: This label provides information such as the
Model Number, Serial Number, System Number, Assigned Frequency, and
certification numbers.