8. MAINTENANCE
8.1. MAINTENANCE PROCEDURES
8.1.1. Normal Maintenance. Normal maintenance is limited to periodic battery charging and
cleaning the outer surfaces and panels with a damp cloth removing dirt and debris. Ensure the
CHARGE/PROGRAM, ELECTRONIC KEY port, and firing terminals are clean and dry with a
cotton swab. Check for signs of corrosion around and on connector pins. Ensure the electric
detonator firing terminals are clean, and easy to depress.
8.1.2. Scheduled Maintenance. It is recommended that the 1673 RFD be returned to the
manufacturer or an authorized service shop every two years for periodic maintenance. At this time
the latest improvements are added, fresh battery packs are installed, the radio transceivers are
tuned and verified, and the overall performance of the RFD is thoroughly tested.
8.1.3. Corrective Maintenance. Corrective maintenance should be performed at the
manufacturer or an authorized service shop only. Replacement of parts or repair at the user level
and field disassembly is strongly discouraged and may result in death, injury, or unsafe equipment
operation. The Remote Unit contains dangerously high voltage levels when armed.
8.1.4. Battery Maintenance. Your RFD contains heavy-duty 7.2V NiMH battery packs that
should be replaced after 500 charge/discharge cycles or every three years, whichever comes first.
If a decrease in run time has developed, there may be a memory problem caused by repeated
shallow discharges or interrupted charge cycles.
8.1.5. Battery Condition (Discharge). To keep the battery packs running optimally, it is
recommended that you perform a full discharge before recharge using the discharge feature of the
at least once per month. To perform a Battery Condition, connect the Charger Power Supply to a
wall outlet, and connect the cable connector to the CHARGE/PROGRAM connector. Turn the unit
on and then press and hold the ‘BATT TEST’ switch for 5 seconds. The unit will discharge the
battery to a low level and then it will be recharged. The whole process takes up to 10 hours to
complete. Always ensure the power supply is connected and working before discharging.
Figure 8-1 Battery Condition (Discharge Battery)