ENGLISH22
• Woodhasanaverageemissivityvalueof(0.86/plywoodoruntreated–unnished
texture)
• Metalhasanaverageemissivityvalueof(0.46/galvanizedpipe)
• Tilehasanaverageemissivityvalueof(0.94/glazedoortile)
• Brickhasanaverageemissivityvalueof(0.93/redbrick)
• Plasterhasanaverageemissivityvalueof(0.67/gypsumwallboard)
• Concretehasanaverageemissivityvalueof(0.95/dry-curedconcrete)
• TouchQuickPickicontoautomaticallyselectthatemissivitylevel/touchemissivity
button
again to lock in selection.
• Iconwillappearinlowerleftcornertoconrmselection.
• Forspecicemissivityandhighestdegreeoftemperatureaccuracy,use
arrows
to change in 0.01 increments.
• Refertoemissivitytableinproductmanual(Figure2)
• Touchemissivitybuttontosaveandlockinselection
(E) Display of Quick Pick emissivity
(F) Menu button
• ToolssettingonROSCOPEi2000
• Selectbetweencameraorvideomodes(cameramodeasdefault)
• SDcardindicatesSDcardstoragedeviceinROSCOPEi2000/opensthumb-nailviewingof
saved images and video
• RefertoROSCOPEi2000manualforsavedimages/video
• RefertoROSCOPEi2000manualforaudiosoundbites
• RefertoROSCOPEi2000manualfordeletingpic’s/videos
(SD Card for Picture /Video storage)
Note: Touch menu icon to access SD card icon . SD card icon opens thumb-nail
view of saved images
(G) Activates / deactivates the floating “hottest” and “coldest” temperature readings on the
screen (default setting on)
(H) Thermometer button allows user to adjust the high / low range of thermal readings
• TouchthethermometerandtheHigh/Lowtemperatureboxesbecomeactivebuttons
(gray background indicates live buttons mode)