RS232 Protocol
11 
Section 2: Feedback String Format 
Standard Response String Format 
Start  Count  ID  Type  Data  Checksum
0xFE 0x31 0xA5 0x20 Char1  …  Char42
Flag1 … Flag5 0xXX 
The feedback string is a representation of the display of the unit. The Char1 - Char42 
data bytes contain ASCII data representing the text that appears across the 2 lines of the 
front display. It can contain source input, volume, and surround mode data and should 
be parsed to obtain this information. 
The Flag1 - Flag5 data bytes contain data on which of the various icons on the front 
display are currently illuminated. The display status uses 2 bits in Flag3 to confirm if the 
front display is On or Off. 
Flag1 – Flag5 Data 
  Flag1  Flag2  Flag3  Flag4  Flag5 
Bit0  A x Display Mode0
SB CBL 
Bit1  5 II Display Mode1
Zone 4  CBR 
Bit2  4  HDMI  Zone 2  Zone 3  SW 
Bit3  3 EX Standby LED < SR 
Bit4  2 ES    > SL 
Bit5  1 dts    7.1 FR 
Bit6  Coaxial Pro Logic    5.1  C 
Bit7  Optical Dolby Digital    Zone  FL 
Display Status 
  Display On  Display Off 
Display Mode 1  0  1 
Display Mode 0  0  0 
12V Trigger Status String Format 
Start  Count  ID  Type  Data  Checksum
0xFE 0x07 0xA5 0x21 Flag1 Flag2 Flag3 Flag4 Flag5  0xXX 
12V Trigger Status Flag1 – Flag5 Data 
  Flag1: All  Flag2: Main  Flag3: Zone 2  Flag4: Zone 3  Flag5: Zone 4 
Bit0  Trigger 1  Trigger 1  Trigger 1  Trigger 1  Trigger 1 
Bit1  Trigger 2  Trigger 2  Trigger 2  Trigger 2  Trigger 2 
Bit2  Trigger 3  Trigger 3  Trigger 3  Trigger 3  Trigger 3 
Bit3  Trigger 4  Trigger 4  Trigger 4  Trigger 4  Trigger 4 
Bit4  Trigger 5  Trigger 5  Trigger 5  Trigger 5  Trigger 5 
Bit5  Trigger 6  Trigger 6  Trigger 6  Trigger 6  Trigger 6 
Bit6   
Bit7   