RS232 Protocol

1
Rotel RSP-1572
RS232 HEX Protocol
The RS232 protocol structure for the RSP-1572 is detailed below. This is a HEX
based communication protocol.
Connection Settings
Baud Rate Parity Valid Data Bits Stop Bit Value
Handshaking Data Type
115200 N 8 1 None String
All commands sent to the attached Rotel device must follow the command
structure detailed below, unless specified otherwise. Send only the bytes only, no
spaces, delimeter, etc.
Standard Command String Format
Start Count Device ID Type Key Checksum
0xFE 0x03 0xA5 0x10 0xXX 0xXX
Note: The count byte only includes the ID, Type, and Key bytes; it does not include the
Start or Checksum bytes.
Note 2: Do not include any carriage returns or line feeds after the commands
Communication Protocol
Command and response messages are included on the following pages. The
standard response string of the unit mirrors the data that would be available on the front
panel of the unit.
Any change to the status of the front display on the unit will prompt a feedback string
mirroring that change.
Note that the spaces shown between hex bytes below are for clarity only; do not include
spaces in the actual command sent to the unit.
Date Version Update Description
February 3, 2012 1.00 Original Specification
August 12, 2014 1.01 Corrected an error with the Max volume command

Summary of content (12 pages)