Owner's Manual
13
English
be broadcast to all Zones 1- 4. The unit will resume the previous Source
Input after approximately 10 seconds of no audio on the INPUT A source.
Valid settings include: DISABLED (Default), ENABLED.
• PA OVERRIDE VOL: This sets the volume level of ZONE 1 - 4 when the PA
OVERRIDE function is activated. “45” is the factory default.
Valid settings include: 0 ~ 96. Default: 45.
• NETWORK WAKEUP: When set to Enabled the unit will maintain the Ethernet
IP connection even in Standby Mode allowing the unit to be powered on
via IP. If Disabled the unit will not power on from the IP connection and
must use either the front panel or RS232 to power on the unit.
Valid settings Include: DISABLED (Default), ENABLED.
NOTE: When Network Wakeup is enabled the unit will consume
additional power.
• NETWORK SETUP: In most systems, set the IP ADDRESS MODE to DHCP.
This setting will allow your router to assign an IP address to the unit
automatically. If your network uses xed IP addresses, set the IP ADDRESS
MODE to STATIC.
Valid settings Include: DHCP (Default), STATIC.
If STATIC mode is selected you must congure all settings for the network
including IP Address, Subnet Mask, Gateway and DNS Server. Press the
ENTER button to activate the rst digit in the line you want to change, then
use the ‹/› buttons to adjust the values and press the ENTER button to cycle
to the next digit. When the proper IP information is congured press the
ENTER button to move the cursor back to the previous menu and accept
the settings. After entering the STATIC IP address information the network
will be tested and connection status reported.
NOTE: For more information regarding network connection please
contact your authorized Rotel dealer.
NOTE: A network connection is not required for the unit to operate.
• NETWORK INFO: Shows the network information. Press the ENTER button
to view Network Connetion Status, IP Address, Subnet Mask, Gateway
and MAC Address.
• SOFTWARE VERSION: This shows the current software version loaded
into the unit.
• SOFTWARE UPDATED: The software can be updated if the unit is properly
connected to the Internet.
• Press the ENTER button on the front panel to check if a new software
version is available.
• If a new software version is available, use ‹/› arrow buttons to select
“UPDATE“ option and press the ENTER button to begin the software
update process.
• The new software will be downloaded from the Internet. The amplier
will power cycle when the software update is complete.
NOTE: Do NOT power off the unit during the software update process.
NOTE: It is recommended to Reset Factory Defaults after the software
update is complete.
• FACTORY DEFAULT: This sets the unit back to the original state as when it
left the factory. Press the ENTER button on the front panel to enter factory
reset menu. Use the / arrow buttons to select YES and press the ENTER
button again to begin reset, or select NO to cancel.
NOTE: All previously congured options will be erased and reset to
the factory default settings.
• EXIT: Exits this SETUP menu.
Troubleshooting
Most difculties in audio systems are the result of incorrect connections, or
improper control settings. If you encounter problems, isolate the area of the
difculty, check the control settings, determine the cause of the fault and
make the necessary changes. If you are unable to get sound from the unit,
refer to the suggestions for the following conditions:
Power Indicator Is Not Illuminated
The Power Indicator and the basic items in the Display window should be
illuminated whenever the unit is plugged into the wall power outlet and the
Power button is pushed in. If it does not illuminate, test the power outlet with
another electrical device, such as a lamp. Be sure the power outlet being
used is not controlled by a switch that has been turned off. If using 12V
trigger power-on, make sure that a trigger signal is present at rear panel
12V TRIGGER IN connector.
Fuse Replacement
If another electrical device works when plugged into the power outlet, but
the Power Indicator still will not illuminate when the unit is plugged into
the wall outlet, it indicates that the internal power fuse may have blown.
If you believe this has happened, contact your authorized Rotel dealer to
get the fuse replaced.
No Sound
Check the signal source to see if it is functioning properly. Make sure the
cables from the signal source to the amplier inputs are connected properly.
Be sure the Input Source is set to the proper input. Check the wiring between
the amplier and the speakers.
Playable Audio Formats
Optical
Format Notes
SPDIF LPCM
44.1k, 48k, 88.2k, 96k, 176.4k, 192k
16 bit, 24 bit