6.6.8 2-Way Voice Behavior
The HLX-40 panel enables the CMS operator to open a 2-way voice session
with the panel. The only events used in 2-way voice are: TAMPER,
EMERGENCY, and ALARM/RESTORE.
In general, the 2-Way Voice Behavior option is achieved via simple telephone
communication. The CMS operator can listen, talk, or close communication by
selecting #1 (Listen), #3 (Talk), or #9 (Close communication) in the event the
system calls when an alarm is sounded. The installer can set the following
options:
CMS 2-way voice Enable/Disable
CMS 2-way voice Timeout
However, if the TROUBLE, BYPASS, and MISC events are reported, and the
CMS is in LISTEN-IN mode, the CMS receptionist can hear the alarm/emergency
voice message events, assuming they belong to the same CMS. On the other
hand, if those events belong to another CMS, they are reported after the
current CMS session report has finished.
To set up 2-way voice behavior:
1. In the
2WV SETUP
menu, select CS 2WV ENABLE.
2. Select ENABLE.
3. Select CS 2WV TIMEOUT.
4. Enter a timeout value that does not exceed 240 seconds.
It is recommended to use 180 seconds for a timeout value.
5. Press Exit to return to Normal mode.
6.6.9 Number of Rings
Specify the number of rings before the system answers the line. By default, this
option is set to 4 rings.
To specify the number of rings:
1. Using the numeric keypad, set the number of rings to between 1 and 15.
2. Press Enter to confirm.
6.6.10 Select Region/Country
Select the region/country for the telephone line DAA, matching the time set
for the system. By default, this option is set to Other.
To select the region:
1. Use the Menu button to select one of the available regions.