Specifications

Installer Menu
HLX-40 Installer Manual 39
6.5.12 Trouble Beeps
This parameter determines whether the system emits a “trouble beep”
indicated by a series of four short beeps once a minute for the following
“Trouble” events:
Low battery (detectors and system)
Supervision loss (detectors)
Power (AC) failure (system)
Communication failure (system)
Tamper (system and zones)
RF jamming
Short circuit in wired zone
The default is set to Disabled
The HLX-40 allows you to enable the beeps for daytime only 8:00 AM to 8:00
PM.
To specify trouble beeps:
1. Using the Menu button, choose Disable, Day & Night (enable), or Day
Only for the trouble beeps.
2. Press Enter to confirm.
6.5.13 Bypass Option
Specifies either manual bypassing of individual zones, or enables the system to
forcedly arm open zones when armed. Bypass is turned off by default.
To set bypass:
1. Using the Menu button, select one of the following options:
Off to set the bypass off
Off/Force allows forced arming (automatic bypass) only
Manual allows manual bypass only
Manual/Force allows both forced arming (automatic bypass) and
manual bypass
2. Press Enter to confirm.
6.5.14 Quick Arm
Enables the user to arm the system without entering a code; Quick Arm is set
to disable by default.
To enable/disable quick arm without a code:
1. Using the Menu button, select either Enable or Disable.
2. Press Enter to confirm.
To utilize quick arm:
1. Press continuously on the AWAY or HOME keys to arm AWAY or
HOME.