Specifications
Installer Menu
38 HLX-40 Installer Manual
6.5.9 Supervision Time
The supervision time submenu specifies the time limit during which the system
receives supervision reports from specified wireless devices. If a device does not
report in at least once within the specified time limit, the system initiates an
inactivity alert. The default supervision time is set to one hour.
To specify the supervision time:
1. Using the Menu button, select one of the time limit options, 20 minutes,
1, 2, 4, 6, 8, 16, 24 or 48 hours.
2. Press Enter to confirm.
6.5.10 Jamming
Specifies whether the system detects and reports jamming – interferences of
the radio channel used by the system.
The jamming detection is disabled by default.
To specify jamming detection:
1. Using the Menu button, select one of the following options:
Disabled: to disable jamming detection
EN enabled: to enable European standard jamming detection
UL enabled: to enable US standard jamming detection
2. Press Enter to confirm.
6.5.11 No Activity Time
Specifies the time limit in which the system should receive a signal from a
sensor used to monitor the activity of sick, elderly or disabled people. If no
device detects and reports movement at least once within the specified time
limit, a “not active alert” sounds and a report is sent to the CMS (if reporting is
enabled). This option is disabled by default.
The behavior of the no activity zone feature varies when in Arm or Disarm
modes:
• When Disarmed – Alert is sent to CMS
•
When Armed – An alarm is heard and an alert is sent to CMS
To set the no activity time:
1. Using the Menu button, select one of the following options:
1, 2, 5, 10, 15, or 30 minutes
Disable the timer
2. Press Enter to confirm.
Required zones’ “No Activity” option should be set to ‘Enabled’ for this security
feature to work.