Specifications
Installation
22 HLX-40 Installer Manual
Figure 8: Wiring to External Siren
This output can be programmed by the installer to provide normally closed or
normally open dry contact output. This relay output toggles the normal
position in case of an alarm and operates in the same method as the local
siren.
4.4.4 Wiring Auxiliary Outputs 1 and 2
Auxiliary outputs 1 and 2: This pair of outputs is an open collector with sink
current limited at 200 mA. The outputs work by connecting an external device
to power supply through an internal transistor in order to turn it on.
Figure 9: Wiring to Aux Outputs
Both Aux 1 and Aux 2 have the same selection of programming. When
programming the Aux 1 and Aux 2 open collector outputs, it is possible to
select from several operational modes from the programming menu as
described in Sections 6.7 and 6.7.2.
4.4.5 Wiring the ZONE 1 Wired Input
Wire input zone 40 for wired door detector.
The wired zone is disabled by default to work with a wired zone. The option
needs to be enabled by the installer.
Figure 10: Wiring to Zone 1 Input
Inside HLX-40