User manual
System Overview 
20  HLX-40 User Manual 
Key    Press to 
7 
Normal mode 
only 
  Record User Message 
Record a voice message of up to fifteen seconds. Press 
and hold the 7 
key for three seconds to erase a message.
8 
Normal mode 
only 
  Event Log Display 
Press once and your Master user code to display the 
event log. The first line of the display shows the event 
log (for example Burglar Alarm). The second line shows 
the zone description or system. 
Press Enter to toggle view between zone description 
and the Time & Date. 
Press Menu to display the next event. 
Press Esc to exit. 
9 
Normal mode 
only 
  Play User Message 
Listen to voice messages. 
4.4  Sound Indicators 
Table 5 describes the sounds are emitted by the system and keypad: 
Table 5: Sound Indicators 
Sound  Sounded When 
Single beep 
A key is pressed 
Long Beep 
Illegal key entry 
Three short beeps 
An entry is successfully accepted. 
Four short beeps a 
minute 
If enabled, on trouble condition. 
Short beep every 
second 
An exit/entry delay is activated. (Beep sounded every 0.5 
seconds during last 10 seconds of delay. 
Chime 1 & 2 
Two (2) various chime sounds, when feature is activated 
Chime 3 
Vocal announcement of “Zone Name” + Open  
Aside from the indication sounds, the system also has a voice confirmation of 
various events. 
This table does not include actual alarm sounds. 
Note that the audible indication of a fire zone differs from that of a normal 