User manual
Technical Specifications
HLX-40 User Manual 13
3. Technical Specifications
Electrical Characteristics
External Power Supply
220 VAC/50 Hz, 110 VAC/60 Hz
Operating Voltage Range
15 VDC, 800 mA
Input Current
Standby: 120 mA
Max: 500 mA (750 mA w/GSM expansion)
Internal Backup Battery
800 mAh for 6 hours standby
Auxiliary Power Output
13.8 VDC, 500 mA max
Display
Two Line, 16 characters, white backlit LCD
PGM Open Collector Outputs
Two fully programmable, 200 mA, PTC protected
External Siren Output
1 A relay
Local Siren
80 dBA
Communication (RF) Characteristics
Frequencies
433.92 MHz (G version)
868.35 MHz (H version)
RF Jamming Detection
UL/EN selectable
Anti-collision
Proprietary RF protocol
Programmable No-activity Timer
1–30 hours, per zone
Reporting
Three private telephone numbers.
Two-Way Voice Communication
Three private telephone numbers
Telephone and Modem
Built in dialer & 2400 Baud modem
Environmental Characteristics
Operating Temp. Range
32ºF – 140ºF (0ºC – 60ºC) without battery
32ºF – 113ºF (0ºC – 45ºC) with battery
Storage Temp. Range
-13ºF – 158ºF (-25ºC – 70ºC)
Operating Humidity
0– 85% at 30ºC non-condensing
Dimensions
HLX-40 HLX-40A HLX-40B
Height x Width x
Depth
217 x 144 x 48 mm
(8.54 x 5.67 x 1.89
in.)
217 x 144 x 50 mm
(8.54 x 5.67 x 1.97
in.
217 x 144 x 48 mm
(8.54 x 5.67 x 1.89
in.)
Weight
520g (1.15 lb) 530g (1.17 lb) 548g (1.21 lb)