User manual

Operating the HLX-40
12 HLX-40 User Manual
2.3.6 Forced Arming
If Forced Arming is enabled, the system is able to arm even when zones are in
violation (open) but not defined as bypassed. In such a case, the system arms,
effectively bypassing the open zone. Once the open zone is closed, the system
completes arming, adding the previously bypassed zone to the monitored
zones.
2.4 Entry/Exit Delay Options
Entry and Exit actions delay the alarm mode and allow the system to ignore
zone violations, as described below.
2.4.1 Entry Delay
Entry delay allows the user a grace period for the time it takes to open the
door and reach the keypad to disarm the system.
If a zone of type Delay is violated while the system is armed (except Instant
Arming), the system does not enter Alarm mode during the Entry Delay period
setting. If the delay has transpired and the system still has not been disarmed,
the system enters Alarm mode.
During Entry Delay, the system signals the keypads to sound warning beeps at
two rates: slower rate at first and faster rate during the last 10 seconds of the
delay period.
2.4.2 Exit Delay
Exit delay allows the user a grace period for the time it takes to reach the door
from the keypad when arming the system upon exit.
When arming a panel, the system ignores zone violations of the predefined
delay zones during the Exit Delay period. Once the delay has transpired, the
system enters Armed mode.
During Home arming, the system ignores all interior zones as well as the
predefined delay zones.
The system may be disarmed during the Exit Delay period.
During Exit Delay, the system emits warning beeps at two rates: slower rate at
first followed by a faster rate of beeping during the last 10 seconds of the
delay period.