Installation Manual

LECTUS duo 3000 readers Connection | en 31
Bosch Security Systems B.V. 2020-10 | V02 |
Switch 5 Switch 6 Switch 7 Switch 8 Address
Off Off On On 3
Off On Off Off 4
Off On Off On 5
Off On On Off 6
Off On On On 7
On Off Off Off 8
3.2.5 Resetting OSDP-key
To delete the OSDP secure channel data, execute these steps:
1. Power-off the reader (e.g. by disconnecting the reader from
the AMC).
2. Set the reader DIP switches 5 to 8 to OFF.
3. Power-on the reader (e.g. by connecting the reader to the
AMC).
4. Wait until the reader continuously flashes the green LED
The green LED flashing indicates that the OSDP secure
channel data has been deleted.
5. Power-off the reader (e.g. by disconnecting the reader from
the AMC).
6. Set the correct reader DIP switch address (
Configuring the
reader (DIP switches), page 27
).
7. Power-on the reader (e.g. by connecting the reader to the
AMC).
Refer to
Configuring the reader (DIP switches), page 27
3.3 Troubleshooting
In case of malfunction of the reader, check these points:
Is the correct power supply on the plugs of PIN 1 (8.5 VDC
to 16 VDC) and PIN 2 (0 V)?