Installation Manual
Table Of Contents
LECTUS duo 3000 readers Connection | en 31
Bosch Security Systems B.V. 2020-10 | V02 |
Switch 5 Switch 6 Switch 7 Switch 8 Address
Off Off On On 3
Off On Off Off 4
Off On Off On 5
Off On On Off 6
Off On On On 7
On Off Off Off 8
3.2.5 Resetting OSDP-key
To delete the OSDP secure channel data, execute these steps:
1. Power-off the reader (e.g. by disconnecting the reader from
the AMC).
2. Set the reader DIP switches 5 to 8 to OFF.
3. Power-on the reader (e.g. by connecting the reader to the
AMC).
4. Wait until the reader continuously flashes the green LED
– The green LED flashing indicates that the OSDP secure
channel data has been deleted.
5. Power-off the reader (e.g. by disconnecting the reader from
the AMC).
6. Set the correct reader DIP switch address (
Configuring the
reader (DIP switches), page 27
).
7. Power-on the reader (e.g. by connecting the reader to the
AMC).
Refer to
– Configuring the reader (DIP switches), page 27
3.3 Troubleshooting
In case of malfunction of the reader, check these points:
– Is the correct power supply on the plugs of PIN 1 (8.5 VDC
to 16 VDC) and PIN 2 (0 V)?