Technical Specifications
54 AC-Q4x Series Installation and Programming Manual
5. Technical Specifications
AC-Q41HB AC-Q42HB
AC-
Q41SB
AC-Q41HP
AC-Q42SB
AC-Q42HP
AC-Q44
Input
Voltage
VDC 12–24 VDC
VAC 12–24 VAC 16–24 VAC 12–24 VAC 16–24 VAC
Maximum
Input
Current (12
VDC)
Heater
Off
130 mA 125 mA 145 mA 130 mA 145 mA 125 mA
Heater
On
610 mA 605 mA 625 mA 610 mA 625 mA N/A
Standby
Input
Current (12
VDC)
Heater
Off
70 mA 65 mA 85 mA 70 mA 85 mA 65 mA
Heater
On
550 mA 545 mA 565 mA 550 mA 565 mA N/A
Maximum Relay
Current
2 A
REX Input
Normally Open (dry contact)
Aux. Input Normally Open (dry contact)
Max. Proximity
Read Range*
N/A 65 mm (2.5
in.)