Programming Manual
Table Of Contents
- 1. Introduction
- 2. Installation
- 3. Operation
- 4. Programming
- 4.1 Entering the Programming Mode
- 4.2 Exiting the Programming Mode
- 4.3 Changing the Open Code
- 4.4 Changing the Auxiliary Code
- 4.5 Changing the Programming Code
- 4.6 Changing the Normal/Secure Code
- 4.7 Changing the Normal/Bypass Code
- 4.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 4.9 Setting Auxiliary Modes
- 4.10 Keypad Heater Operation
- 4.11 Setting the Lockout Feature
- 4.12 Setting the Backlight Behavior
- 4.13 Enrolling Primary and Secondary Codes
- 4.14 Deleting Primary and Secondary Codes
- 4.15 Relay Codes Assignment
- 4.16 Changing PIN Code Length/Factory Default Settings
- 4.17 Replacing a Programming Code
- 4.18 Replacing a Normal/Secure Code
- 5. Technical Specifications
Programming
34 AC-Q4x Series Installation and Programming Manual
You hear three beeps.
The system returns to Normal mode.
4.8 Setting Fail Safe/Secure Operation,
Tamper Siren and Lock Strike Release
Time
The default value is 0004, which corresponds to Fail Secure
operation, no siren, and 4-seconds Lock Strike release time.
To set the Fail Safe/Secure Operation, Tamper Siren and Lock
Strike Release Time:
1. Enter Programming mode.
2. Press 6 to enter Menu 6.
The left LED flashes green.
3. Construct a code using the following
instructions:
First digit
For Fail Secure Operation, the first digit should be 0.
For Fail Safe Operation the first digit should be 1.
Second digit
Siren Time in minutes (1–9, 0 – disabled)
Third and fourth digits
Enter the number of seconds (from 1 to 99) that you want
the Lock Strike to be released.
For example, 0312
means a Fail Secure Operation consisting of
a 3-minute siren and a 12-second Lock Strike release time.
Green
Green
Green
Green