Programming Manual
Table Of Contents
- 1. Introduction
- 2. Installation
- 3. Operation
- 4. Programming
- 4.1 Entering the Programming Mode
- 4.2 Exiting the Programming Mode
- 4.3 Changing the Open Code
- 4.4 Changing the Auxiliary Code
- 4.5 Changing the Programming Code
- 4.6 Changing the Normal/Secure Code
- 4.7 Changing the Normal/Bypass Code
- 4.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 4.9 Setting Auxiliary Modes
- 4.10 Keypad Heater Operation
- 4.11 Setting the Lockout Feature
- 4.12 Setting the Backlight Behavior
- 4.13 Enrolling Primary and Secondary Codes
- 4.14 Deleting Primary and Secondary Codes
- 4.15 Relay Codes Assignment
- 4.16 Changing PIN Code Length/Factory Default Settings
- 4.17 Replacing a Programming Code
- 4.18 Replacing a Normal/Secure Code
- 5. Technical Specifications
Programming
AC-Q4x Series Installation and Programming Manual 33
3. Enter the new 4-digit Normal/Secure code.
You hear three beeps.
The system returns to Normal mode.
4.7 Changing the Normal/Bypass Code
The Normal/Bypass code is also used to turn the door chime off
and on. Chime only functions with the BL-D40 external sounder.
• The chime is only heard when the Lock Strike relay is activated by a
valid code entry.
•
Code 0000 erases and deactivates the Normal/Bypass code.
To change the Normal/Bypass code:
1. Enter Programming mode.
2. Press 5 to enter Menu 5.
The left LED flashes orange.
3. There are four different ways to program the Normal/Bypass
code and door chime:
Disable both Bypass code and the door
chime. Enter the code 0000.
Disable Bypass code and enable the door
chime. Enter the code 0001.
Enable Bypass code and disable the door
chime. Enter any code ending with 0.
Enable Bypass code and enable the door
chime. Enter a code not ending with 0.
Orange
Green
Green