Programming Manual
Table Of Contents
- 1. Introduction
- 2. Installation
- 3. Operation
- 4. Programming
- 4.1 Entering the Programming Mode
- 4.2 Exiting the Programming Mode
- 4.3 Changing the Open Code
- 4.4 Changing the Auxiliary Code
- 4.5 Changing the Programming Code
- 4.6 Changing the Normal/Secure Code
- 4.7 Changing the Normal/Bypass Code
- 4.8 Setting Fail Safe/Secure Operation, Tamper Siren and Lock Strike Release Time
- 4.9 Setting Auxiliary Modes
- 4.10 Keypad Heater Operation
- 4.11 Setting the Lockout Feature
- 4.12 Setting the Backlight Behavior
- 4.13 Enrolling Primary and Secondary Codes
- 4.14 Deleting Primary and Secondary Codes
- 4.15 Relay Codes Assignment
- 4.16 Changing PIN Code Length/Factory Default Settings
- 4.17 Replacing a Programming Code
- 4.18 Replacing a Normal/Secure Code
- 5. Technical Specifications
Programming
AC-Q4x Series Installation and Programming Manual 29
Menu
No.
Description Default Section
4
Digits
5
Digits
6
Digits
4-8 Digits
Backlight and LED
Behavior
5100 4.12
7 Enroll proximity cards, PIN
or both
NA 4.13
8 Delete proximity cards or
PIN
NA 4.14
9 Code assignment with
strike/auxiliary
NA 4.15
0 Return to factory
defaults/Change PIN code
Length
NA 4.16
4.1 Entering the Programming Mode
• The controller must be in Normal mode to enter the programming
mode.
• The factory default 4-digit programming code is 1234.
• If a Programming code is not entered within 5 seconds, the
controller returns to Normal mode.
To enter Programming mode:
1. Press # twice.
The left LED turns off and the right LED turns
red.
2. Enter your 4-digit Programming code.
The right LED turns green.
Red