Instruction manual

Page 12
07/04
AC-Q41H
Page 13
07/04
AC-Q41H
Wiring Diagrams
Wiring the Auxiliary Input and Output
(-)
ELECTRIC LOCK
STRIKE
COM
N.C.
N.O.
REX / BL
COM
N.C.
N.O.
IN / MONITOR
LOCK
AUX.
V IN
+
-
REX / BL
(-)
(-)
(+)
(+)
FAIL SAFE
or
FAIL SECURE
REX
COMMON
POWER SUPPLY
12V - 24V DC
or
16V - 24V AC
FROM TRANSFORMER
Transorb: 1.5KE47C - Connect to load terminals
(Optional transorb, Not Supplied)
COM
N.C.
N.O.
REX / BL
COM
N.C.
N.O.
IN / MONITOR
LOCK
AUX.
V IN
+
-
COMMON
POWER SUPPLY
(-)
(+)
12V - 24V DC
or
16V - 24V AC
FROM TRANSFORMER
Auxiliary
Load
AUXILIARY
INPUT
(MONITOR)
(-)
AUX. IN
IN / MONITOR
Transorb: 1.5KE47C - Connect to load terminals
(Optional transorb for inductive loads, Not Supplied)
AC-Q41H
AC-Q41H