Enabling or Disabling the
built in keypad heater
The factory default setting for the keypad heater is disabled 3000.
The AC-Q41H contains a built-in keypad heater. When the keypad
heater is enabled the keypad heater will activate when the ambient
temperature drops to approx. 37 F to 41 F (3 C to 5 C) and will
remain active until the keypad temperate rises to approx 43 F to 48
F (6 C to 9 C).
When the heater is enabled the AC-Q41H's lowest operating
temperature is -4 F (-20 C). When the heater is disabled the AC-
Q41H's lowest operating temperature is 32F (0 C).
1) Enter Programming Mode
2) Press "6" to enter Menu 6
The Mode LED will flash green
3) Construct the 4-digit code
using the instructions below:
Fourth Digit
To DISABLE the heater the fourth
digit should be "0"
To ENABLE the heater the fourth
digit should be "1"
Mode Door
GREEN
Mode Door
GREENGREEN
3
0
0
?
AUXILIARY MODE 7
In auxiliary mode 7 the AC-Q41H can trigger the auxiliary relay if it
detects that the door has been ajar too long. In this mode the
auxiliary input should be wired to the magnetic contact switch on
the door. The auxiliary relay should be wired to the alarm system. If
the door is opened the controller will wait for the door ajar delay
time, if the door does not close before the ajar delay time the
controller will activate the auxiliary relay. The auxiliary setting
defines the door ajar time.
If the BL-D40 is connected and an ajar event occurs the BL-D40 will
chime every few seconds for 1 minute or till the door is closed.
AUXILIARY MODE 8
In auxiliary mode 8 the AC-Q41H can function as a two door
controller and also provide LED Control functionality. The auxiliary
relay should be attached to the lock on the second door. The
auxiliary setting defines the door open time for the second door.
The auxiliary input is used to control the LED. If the auxiliary input is
open the Door LED will flash red, if the auxiliary input is closed the
Door LED will flash green.
Note: This mode takes control of the Door LED. The Door LED will
no longer activate when a valid code is entered or when in
Secure Mode waiting for a Secondary Code to be entered.
AUXILIARY MODE 9
In auxiliary mode 9 the AC-Q41H can function as a two door
controller and also provide LED Control functionality. The auxiliary
relay should be attached to the lock on the second door. The
auxiliary setting defines the door open time for the second door.
The auxiliary input is used to control the LED. If the auxiliary input is
open the Door LED will flash green, if the auxiliary input is closed
the Door LED will flash red.
Note: This mode takes control of the Door LED. The Door LED will
no longer activate when a valid code is entered or when in
Secure Mode waiting for a Secondary Code to be entered.