INSTRUCTION MANUAL 1 2 3 4 5 6 7 8 9 0 # AC-Q41H VANDAL RESISTANT STAND-ALONE ACCESS CONTROL UNIT 07/04
Contents INTRODUCTION Replacing a lost Programming Code Replacing a lost Normal / Secure Code 4 5 7 Technical Specifications Key Features 42 42 APPENDIX INSTALLATION Mounting the AC-Q41H Controller Wiring Diagrams 9 9 12 FEATURES AND CONCEPTS Normal, Secure, & Master Users Modes Of Operation Changing the Modes of Operation Auxiliary Output and Input Request To Exit (REX) Button Case and Back Tamper BL-D40 External Sounder 15 16 17 18 19 19 20 PROGRAMMING THE AC-Q41H 21 22 22 23 23 24 25 25 25 27 2
Introduction Technical Specification The AC-Q41H is a vandal resistant keypad access control unit suitable for internal or external applications. Electrical Characteristics The unit accepts up to 500 users and provides entry via the use of PIN codes.
Mechanical Characteristics Key Features Dimensions: 4.72" (120mm) L x 3" (76mm) W x 0.85"(22mm) D Here are some of the AC-Q41H's key features: Weight: 1.
Mounting the AC-Q41H Controller Case Screw Door LED 3 x 4 Matrix Keypad Installation 1) Before starting, select the location to mount the AC-Q41H controller. 2) Drill holes into the back cover according to how you want to mount the AC-Q41H. (See explanation and diagram below). US Gang Box There are two hole indicators on the back of the metal cover specifically for the US Gang Box.
5) Screw the AC-Q41H back cover to its mounting location. 7) Return the front cover of the AC-Q41H to the mounted back plate. 8) Secure the front cover by using the supplied security screw in the controllers accessories kit. An L-Shaped tool is provided for use when tightening the security screw. Wiring the AC-Q41H A few of the typical wiring diagrams are shown on the next three pages; for other wiring diagram examples refer to the support section of the Rosslare Web Site.
Wiring Diagrams Wiring the Auxiliary Input and Output AC-Q41H V IN AUX. LOCK V IN AUX. COMMON POWER SUPPLY REX / BL (+) REX FAIL SAFE or FAIL SECURE (+) (-) (-) (+) AUXILIARY INPUT (MONITOR) 12V - 24V DC COMMON POWER SUPPLY ELECTRIC LOCK STRIKE AUX. IN IN / MONITOR COM N.C. N.O. IN / MONITOR LOCK +- COM N.C. N.O. IN / MONITOR +- COM N.C. N.O. REX / BL COM N.C. N.O.
Normal, Secure, & Master Users Wiring the BL-D40 External Sounder The AC-Q41H accepts up to 500 users and provides entry via the use of PIN codes. Each user is provided with two code memory slots, Memory Slot 1 (Primary Code) and Memory Slot 2 (Secondary Code). The way in which the two memory slots are programmed determines a users access level and also determines the way in which the AC-Q41H grants access in its three Modes of Operation. AC-Q41H COM N.C. N.O. REX / BL +- COM N.C. N.O.
Changing the Modes of Operation Modes of Operation Changing from Normal Mode to Secure Mode: The AC-Q41H has 3 Modes of Operation: Mode 1) Normal Mode. = Mode LED is green Door Normal Mode is the default mode. In Normal Mode the door is locked until a Primary Code is presented to the controller. The controller can only be programmed in Normal Mode. 2) Bypass Mode. l Mode LED is orange Mode Mode Mode LED will flash red Door RED 2) Press the "#" key to confirm the Mode change.
Changing from Normal Mode to Bypass Mode: Request to Exit (REX) Button By default there is no Normal / Bypass code. The Normal / Bypass code must first be programmed to use this function. Refer to page 24 to create / modify the Normal / Bypass Code 1) Enter the 4 digit Normal / Bypass Code. l Mode LED will flash orange Mode Door GREEN Mode Door ORANGE 2) Press the "#" key to confirm the Mode change.
BL-D40 External Sounder Programming the AC-Q41H The BL-D40 External Sounder is designed to operate indoors and installed within the premises to be secured. The Sounder can be powered by 16 to 24V DC power supply or by 16 to 24V AC from a transformer. The BL-D40 is capable of emitting four different types of alerts both audible and visual; Bell, Door Chime, Siren, and Strobe Light. 1) The Bell always sounds when the controller's door bell button is pressed.
Entering Programming Mode 1) Press the "#" key two times within 2 seconds. l Mode LED will turn off l Door LED will turn red 2) Enter your 4-digit Programming Code. If the Programming Code is valid the door LED will turn green and the AC-Q41H will be in Programming Mode. Changing the Open Code Mode Door RED 1 2 3 The Default Factory Setting for the Open Code is 2580.
1) Enter Programming Mode Mode Door GREEN 2) Press "2" to enter Menu 2 l The Mode LED will turn orange 3) Enter the new 4-digit code you wish to set as Auxiliary Code.
a) Disable Bypass Code - Disable Door Chime Enter the 4-digit code 0000 0 0 0 0 0 1 ? 0 b) Disable Bypass Code - Enable Door Chime 0 Enter the 4-digit code 0001 0 c) Enable Bypass Code - Disable Door Chime Enter any 4-digit code ending with 0 ? ? 4) System returns to Normal Mode l You will hear three beeps l The Door LED will turn off l The Mode LED will turn green ? Mode ? The default factory setting is 0004. The Tamper Siren feature requires the BL-D40 External Sounder.
AC-Q41H Page 28 07/04 01 to 99 Aux. Relay Release Time 00 Aux. Relay Toggles N.O. LED Ctrl - Green 9 Valid Code 01 to 99 Aux. Relay Release Time 00 Aux. Relay Toggles N.O. LED Ctrl - Red 8 Valid Code 00 to 99 Ajar Delay N.C. Door Monitor 7 Door Ajar 00 to 99 Forced Delay N.C. Door Monitor 6 Forced Door 00 to 99 Maximum Shunt Time N.C. Door Monitor 5 Shunt 00 to 99 Shunt Time N.O. Normal / Secure Direct Shunt 01 to 99 Aux. Relay Release Time 00 Aux. Relay activated by Tamper N.C.
Auxiliary Mode Reference Guide The following are brief descriptions of each of the AC-Q41H's auxiliary modes. To use these features refer to "Setting the Auxiliary Mode" on page 28. AUXILIARY MODE 0 In auxiliary mode 0 the AC-Q41H can function as a two door controller. The auxiliary relay should be attached to the lock on the second door. The auxiliary setting defines the door open time for the second door. The auxiliary input should be attached to the REX button for the second door.
AUXILIARY MODE 7 In auxiliary mode 7 the AC-Q41H can trigger the auxiliary relay if it detects that the door has been ajar too long. In this mode the auxiliary input should be wired to the magnetic contact switch on the door. The auxiliary relay should be wired to the alarm system. If the door is opened the controller will wait for the door ajar delay time, if the door does not close before the ajar delay time the controller will activate the auxiliary relay.
Enrolling Primary & Secondary Codes Primary Codes Mode 1) Enter Programming Mode - Primary Codes can only be enrolled to an empty User Slot, i.e a slot where there is no existing Primary Code. - Primary Codes must be unique, i.e. one users Primary Code may not be the same as another users Primary Code. - Primary Codes cannot be the same as any system codes, such as the Normal / Secure Code or Open Code. - Users who hold a Primary Code can gain entry during Normal Mode and Bypass Mode.
Enrolling Secondary Codes using the Code Search Method Deleting Primary & Secondary Codes The Code Search feature enables you to quickly enroll a Secondary Code to a user who's slot number is unknown but who's primary code is known. 1) Enter Programming Mode Mode Door GREEN 2) Press "7" to enter Menu 7 l The Door LED will turn orange Mode ORANGE 3) Enter the 3-digit User Slot number 000 l The Door LED will flash orange Door 0 Mode 0 0 Door .
Deleting Primary and Secondary Codes using the Code Search Method 1) Enter Programming Mode Mode Door GREEN 2) Press "8" to enter Menu 8 l The Mode LED will turn red Mode RED 3) Enter the 3-digit User Slot 000 l The Door LED will flash orange Door 0 ORANGE 0 0 Mode Door RED Lock Strike Relay and Auxiliary Relay Code Assignment When a Primary Code is enrolled for any user, that user is assigned rights to activate the Lock Strike Relay when they present a valid code to the controller.
Lock Strike and Auxiliary Relay Code Assignment using the Code Search Method Mode 1) Enter Programming Mode Door Return To Factory Default Settings Warning: GREEN 2) Press "9" to enter Menu 9 l The Mode LED will turn red Mode Door GREEN ORANGE 3) Enter the 3-digit User Slot 000 l The Door LED will flash orange 0 0 0 Mode Door You must be very careful before using this command! Doing so will erase the entire memory which includes all User and Special Codes, and return all codes to their factor
Glossary Replacing a lost Programming Code Note: The AC-Q41H must be in Normal Mode otherwise this will not work. Make sure that the Mode LED is green before proceeding. A 1) Remove power from the AC-Q41H Access Control: Primarily refers to a device or set of devices controlling the entry of people traveling through a door or set of doors. Ajar Delay: The time allowed for a door to be left open before sounding an alert and / or activating the Auxiliary Relay.
F Fail Safe: The system setting in which a total power loss leaves the connected door unlocked. Fail Secure: The system setting in which a total power loss leaves the connected door locked. Forced Door: A door which has been physically opened without the access control device having released the lock. Forced Door Time: The amount of time (user programmed) the controller waits in the event of a Forced Door before the Auxiliary Output is activated.
Limited Lifetime Warranty LIMITED LIFETIME WARRANTY TERMS ,, ROSSLARE ENTERPRISES LIMITED S (Rosslare) LIMITED LIFETIME WARRANTY is applicable worldwide. This warranty supersedes any other warranty. Rosslare's LIMITED LIFETIME WARRANTY is subject to the following conditions: WARRANTY Warranty of Rosslare's products extends to the original purchaser of the Rosslare product and is not transferable.
Technical Support International: Rosslare Enterprises Ltd. 905-912 Wing Fat Industrial Bldg., 12 Wang Tai Road, Kowloon Bay, Hong Kong. http://www.rosslaresecurity.com Tel: Fax: E-mail: (852) 2795 5630 (852) 2795 1508 info@rosslare.com.hk United States and Canada: Rosslare NAPDC Suite 238, 200 East Howard Street, Des Plaines, IL 60018 USA http://www.rosslaresecurity.com Tel: Tel: Fax: E-mail: AC-Q41H (866) 262 8633 (Toll-Free) (847) 827 6330 (Direct) (847) 827 6433 support@rosslare.