Instruction manual

Programming
4.1.1 Entering the Programming Mode
Note:
The controller must be in normal mode to enter the
programming mode.
The factory default 4-digit programming code is 1234.
If a programming code is not entered within 5 seconds, the
controller will return to its normal mode.
1) 5 second . Depress the # key twice, within 0. s
Mode indicator will turn off.
Door indicator will turn red.
Mode
Door
Red
2) Enter your programming code.
If the programming code is valid, the door
Indicator will turn green and the controller will
enter the programming mode.
Mode Door
Green
4.1.2 Exiting the Programming Mode
Note:
Wrong entries may reset the controller back to its normal mode.
If no key is pressed for 1 minute, while in programming mode,
the controller will exit the programming mode and return to its
normal mode.
To exit the programming mode, depress the # key twice, within 0.5
seconds.
You will hear three beeps.
Mode
Door
AC-Q4x Family, Installation and user Manual Page 28
The door indicator will be off.
The mode indicator will turn green.
The above indicates that the controller has returned to its normal
mode.
Green
Note:
While enrolling, deleting users, or while in code assignment
mode, depress the # key, twice to exit the programming mode.