Specifications
Programming
32 AC-F/G4x Family Installation and Programming Manual
You hear three beeps.
The system returns to Normal mode.
5.7 Setting Fail Safe/Secure Operation
In this paragraph, the failsafe/fail secure operation of the door lock
and the Door Lock Strike Release time are set. Setting the sounding
period for the siren feature requires a BL-D40 External Sounder.
To set the failsafe/secure operation:
1. Enter Programming mode.
2. Press 6 to enter Menu 6.
The Mode indicator flashes green.
3. Construct a code using the following instructions:
First Digit
For fail secure operation, the first digit
is set to 0.
For fail safe operation, the first digit is
set to 1.
Second Digit
Siren time, enter any number from 0
to 9 (minutes).
Third and Fourth Digits
The Lock Strike is to be released after
the number of seconds entered (1 to
99).
For example 0 5 1 2 means: fail secure operation (0), with5
minutes Siren time (5) and a 12-second Lock Strike Release time
(12).
Mode
Door
Green
Mode
Door
Green
Mode
Door
Green
Green