Instruction manual

Table Of Contents
Programming
AC-F4x and AC-G4x Family Manual Page 32
AUXILIARY MODE 2
Auxiliary input function: Toggles normal/secure modes
Auxiliary output activated by: Star Button (*)
E.g. In auxiliary mode 2, the auxiliary relay can function as a
general purpose time switch that can be activated when the star
button (Å) is depressed. The auxiliary setting establishes for how
long the auxiliary relay is to be activated. The auxiliary input can
switch the mode of operation of the controller between normal
and secure mode. By connecting a switch timer or alarm system
output to the auxiliary input, the controller can be automatically
switched from normal mode (during office hours) to secure mode
(after office hours).
AUXILIARY MODE 3
Auxiliary input function: Toggles normal/secure modes
Auxiliary output activated by: Alarms
E.g. In auxiliary mode 3, the auxiliary output is activated if the
controller is tampered; that is, if the case is forcibly opened or
removed from the wall. The auxiliary input can switch the mode of
operation of the controller between normal and secure mode. By
connecting a switch timer or alarm system output to the auxiliary
input, the controller can be automatically switched from normal
mode (during office hours) to secure mode (after office hours).