Instruction manual

Table Of Contents
Programming
AC-F4x and AC-G4x Family Manual Page 30
4.8.2 Quick Reference Guide for Auxiliary Mode Setting
Auxiliary
Mode
Auxiliary Input
Function
Auxiliary
Output
Activated by
Auxiliary
Relay
Auxiliary Settings
(in seconds)
0 AUX REX Valid code or
AUX REX
N.O. 01 to 99 Aux. relay release time
00 Aux. relay toggle
1 Normal/Secure
switch
Valid code N.O. 01 to 99 Aux. relay release time
00 Aux. relay toggle
2 Normal/Secure
switch
Star button (Å)
N.O. 01 to 99 Aux. relay release time
00 Aux. relay toggle
3 Normal/Secure
switch
Tamper event N.C. 01 to 99 Aux. relay release time
00 Aux. relay tamper activated
4 Normal/Secure
switch
Direct shunt N.O.
01 to 99 Shunt time
5 Door Monitor Shunt N.C. 01 to 99 Maximum shunt time
6 Door Monitor Forced door N.C. 01 to 99 Forced delay
7 Door Monitor Door ajar N.C. 01 to 99 Ajar delay
8 LED control –
Green
Valid code N.O. 01 to 99 Aux. relay release time
00 Aux. relay toggle
9 LED control - Red
Valid code N.O. 01 to 99 Aux. relay release time
00 Aux. relay toggle