How to Set Up a Site
AxTraxNG™ Software Installation and User Manual 49
Field Description
Door output
polarity is
Normal Closed
Select this checkbox to ensure Fail Safe door opening if the Fail Safe
door Lock Device power fails. Once enabled, the door output relay is
activated when the door is closed and is deactivated when the door
is open. In this configuration, the Fail Safe lock device should be
wired to the door relay N.O. (Normal Open) and COM (Common)
terminals.
Manual Door
Open Enabled
Select this checkbox to allow operators to adjust the door manually
(see Section 5.9).
Door open time Set the duration for which the door stays unlocked.
Extended door
open time
Set the duration for which the door stays unlocked for users with
Extended door open rights.
Door held open
Set the duration for which the door can be held open without raising
an alarm event.
Select the checkbox to use this timer; for the Server application, the
Pop-up and Snapshot section opens.
Note: If this feature is enabled, then the Activity start delay
(Section 5.7) feature for that door must be set to 0.
Door forced
open
Set the duration after which when the door is forced open, an event
occurs.
Select the checkbox to use this timer; for the Server application, the
Pop-up and Snapshot section opens.
Note: If this feature is enabled, then the Activity start delay
(Section
5.7) feature for that door must be set to 0.
To edit the door properties:
1. In the Tree View, click AC Networks.
2. Select a network and expand a panel in the Tree View.
3. Select Doors.
The available doors are listed in the display area
4. Select a door in the display area and click Edit.
The
Door Properties
window opens.