User guide
Table Of Contents
- 1. Introduction
- 2. Specifications and Requirements
- 3. Installation
- 4. System Overview
- 5. How to Set Up a Site
- 5.1 Adding Time Zones
- 5.2 Adding Holidays
- 5.3 Adding a Network
- 5.4 Adding Access Control Panels
- 5.5 Configuring the Doors
- 5.6 Configuring the Readers
- 5.7 Configuring the Inputs
- 5.8 Adding a Camera
- 5.9 Adding Panel Links
- 5.10 Creating Groups
- 5.11 Adding Users and Cards
- 5.12 Adding Departments, Users, and Visitors
- 5.13 Adding Access Areas
- 5.14 Adding Global Antipassback Rules
- 5.15 Car Parking
- 5.16 Adding Operators
- 5.17 Creating Elevator Control
- 5.18 Creating Status Maps
- 6. ViTrax™ Video Integration
- 7. Manual Operation
- 8. AxTraxNG™ Reports
- 9. Administrator Operations
- A. Firewall Configuration
- B. SQL Service Settings
- C. Network Configuration
- D. Restoring Factory Default Settings
- E. Configuring User Counters
- F. Cross Platform Camera Setup
- G. Enrolling Cards using MD-08 Desktop Reader
- H. SQL Server Installation Troubleshoot
- I. AxTrax.NET Watchdog
- J. Adding Custom Wiegand Formats

How to Set Up a Site
46 AxTraxNG™ Software Installation and User Manual
The Antipassback tab contains the following fields:
Table 5: Network > Panel Properties > Antipassback Tab
Field Description
Automatic
Antipassback
From the
Automatic Antipassback
dropdown menu, select
the time zone for door Antipassback rules to apply.
Antipassback severity Choose the antipassback severity:
• Hard – When hard Antipassback is selected, an event is
generated and the door does not open.
• Soft – When soft Antipassback is selected, an event is
generated and the door opens.
In/Out reader list From the IN/OUT readers list, select the checkboxes to apply
Antipassback restrictions to Reader 1 through Reader 8, as
required. The reader antipassback is enabled when the
checkbox is selected.
The
Options
tab contains the following fields:
Table 6: Network > Panel Properties > Options Tab
Field Description
Events filter Click Select to open the Events Filter and select the events that
this panel should record. Set the filter's operation method:
• Always Active – Only the selected events are recorded by
the panel
• Active when panel disconnected – If the panel is
disconnected from the AxTraxNG™ server, only the selected
events are recorded. When the panel is connected to the
server, all events are recorded.
Note: In the default configuration, some events are
filtered and may not be seen in the display area
Events view
Door Interlock Select the Enabled checkbox to enable Door Interlock. Select the
Door 1-8 checkboxes to apply the Door Interlock restrictions to
Doors 1-8.
The Door Interlock function is only enabled when the Enable
checkboxes and a minimum of two doors are selected.
AC-525 USB
Storage
(applicable when
connected to AC-
525 only)
From the Alarm Threshold Range (%) dropdown menu, select
the percentage of available memory consumed to determine
when the system generates the "USB Disk Low Level" event.
The USB disk on key status is monitored roughly once an hour.
Therefore, be sure to select an acceptably low threshold level and
consider that any related alarm may be set off up to one minute
after the actual event occurs.