User guide
Table Of Contents
- 1. Introduction
- 2. Specifications and Requirements
- 3. Installation
- 4. System Overview
- 5. How to Set Up a Site
- 5.1 Adding Time Zones
- 5.2 Adding Holidays
- 5.3 Adding a Network
- 5.4 Adding Access Control Panels
- 5.5 Configuring the Doors
- 5.6 Configuring the Readers
- 5.7 Configuring the Inputs
- 5.8 Adding a Camera
- 5.9 Adding Panel Links
- 5.10 Creating Groups
- 5.11 Adding Users and Cards
- 5.12 Adding Departments, Users, and Visitors
- 5.13 Adding Access Areas
- 5.14 Adding Global Antipassback Rules
- 5.15 Car Parking
- 5.16 Adding Operators
- 5.17 Creating Elevator Control
- 5.18 Creating Status Maps
- 6. ViTrax™ Video Integration
- 7. Manual Operation
- 8. AxTraxNG™ Reports
- 9. Administrator Operations
- A. Firewall Configuration
- B. SQL Service Settings
- C. Network Configuration
- D. Restoring Factory Default Settings
- E. Configuring User Counters
- F. Cross Platform Camera Setup
- G. Enrolling Cards using MD-08 Desktop Reader
- H. SQL Server Installation Troubleshoot
- I. AxTrax.NET Watchdog
- J. Adding Custom Wiegand Formats

Network Configuration
AxTraxNG™ Software Installation and User Manual 115
The upper left window lists all TCP/IP converters attached on the local
network, identified by their MAC address, and indicates if they are
available to be assigned to a new panel network or are already assigned.
5. From the MD-N32 list (the MD-N32's MAC address should be labeled on
the TCP/IP converter), select the appropriate MAC address.
6. In Gateway Type, select the type of TCP/IP converter, MD-N32, MD-IP32
On board, or any other valid option. Skip this selection if it is already valid.
7. Type the Local IP address and Subnet for the computer's network.
8. Enter the Local Port number and select the Speed of your connection. It
is recommended to select a higher value port number (4001 or higher).
Note that the selected should not end with zeros (prefer setting Port value
of 4243 rather than 4200). This avoids colliding with port addresses
reserved for various equipment installed on the same network.
9. Click OK to start the verification process.
10. Turn off the MD-N32 power (or panel power if using the onboard
module, such as MD-IP32), and then turn the power on again. This step is
necessary when using certain versions of MD-N32 or MD-IP32 models.
Skip this step if not applicable.
11. If configuration applies to a WAN network, disconnect the configured unit
from the local network, and reconnect to the WAN network and access
control panels network working over the WAN.
To configure MD-N33 in Ax TraxNG™:
1. In the AxTraxNG™ software, add a new network.
2. Under network type, select Modem.
Communication speed is limited to 9600, 19200, 57600, or 115200 bits per
second.