Unit installation

Input and Output Connections
26 AC-215IP Hardware Installation Manual
When connecting a reader, the following should be defined:
Single door controller:
Door 1 Reader 1 IN/OUT
Door 1 Reader 2 OUT/ IN
Double door controller:
Door 1 Reader 1 IN/OUT
Door 2 Reader 2 IN/OUT
Use the AxTraxNG™ software to set the readers for IN or OUT use and to set
the data transmission format for each reader.
The reader’s tamper output connects to the access control panel's Reader-
Tamper input. If the reader is interfered with, an alarm can be generated.
The panel's Reader G.LED output activates the reader’s green LED input when
operating in "Card and PIN" secure mode. While this mode is in force, users
must enter a PIN on the keypad immediately after entering the card.
The controller activates the LED control for 2 seconds when an access granted
event occurs.