User`s guide
AC-020 Page 50 03/02 
NOTE: This is a 4-digit code. The first digit 
signifies whether the unit is being used 
for fail secure (factory default setting) or 
fail safe operation. The second digit 
signifies the length of time in minutes the 
tamper alarm will sound. The last 2 digits 
signify the time the door release will be 
activated (from 01 to 99 seconds). 
For Fail Secure Operation: 
•  Enter 0 for the first digit 
For Fail Safe Operation: 
•  Enter 1 for the first digit 
For Tamper Alarm: 
•  If the Tamper Alarm is required, enter 1-9 
as the second digit to set the alarm sound 
time from a minute to 9 minutes. 
•  If the Tamper Alarm is not required, enter 0 
as the second digit. 
For Door Release Time: 
•  Enter the number of seconds you wish the 
door release to remain activated. (For 
example, 0512 means fail secure with a 5-
minute tamper alarm sound time and a 12 
second door release.) 
•  You will hear 3 beeps. 
•  The system will return to Normal mode. 
•  Default door open time is 4 seconds. 