User Manual
Table Of Contents
- 1. Introduction
- This wireless expansion transforms the AuraSys( Lite system from a limited hardwired system into a wireless system. The expansion is a two way RF communicator which allows connection to wireless sensors, sirens, keypads, repeaters and remote controls.
- With up to 4/6 zones depending on the hosting panel having the same characteristics as the on board zones.
- The stand alone expansion option is housed in a plastic casing installed outside of the system's case considering RF environment and wireless devices deployment.
- 2. Technical Specifications
- Auxiliary Voltage: 13.4 – 13.8 VDC from hosting panel
- Maximum Input Current: 55-75 mA
- Indication: Red LED
- Operating Environment: indoor use
- Operating Temperature: -10°C to 50°C (14°F to 122°F)
- Operating Humidity: 0 to 95% (Non-Condensing)
- RFI Protection: >20 V/m up to 1000 MHz.
- Dimensions (HxWxD): 101 x 99 x 35 mm (4 x 3.9 x1.4 in)
- Weight: 143 g (0.316 lbs)
- XR-16AH – 868.35 MHz
- XR-16AG – 433.92 MHz
- 3. Installation
- The XR-16A is designed for easy installation. Only a few steps are required to install the keypad.
- Changes or modifications to this equipment not expressly approved by Rosslare security as the party responsible for compliance could void the user’s authority to operate the equipment.
- Perform the following steps to mount the expansion:
- 1) Remove the four screws holding the front cover. Set the screws aside.
- 2) Disassemble the PCB assembly from the back plate, remove the four screws holding the PCB, set them aside.
- 3) Locate the back plate at the desired installation location. The wireless expansion should be installed at a secured location considering RF environment and wireless devices deployment.
- 4) Use the back cover itself as a template for the wall screws.
- 5) Drill holes in the wall and insert anchors. Hardware is provided.
- 6) Route a four-wire cable from the panel to the wireless expansion location.
- 7) Pass the 4-wire cable via one of the channels designed in the back plate. Use pliers to remove the section covering the channel.
- 8) Mount and fasten the back plate using the screws provided. Make sure to level the plate.
- 9) Make wiring connections, to the PCB assembly and mount on the back plate.
- 10) Secure with the screws, set aside previously.
- Refer to the wiring diagram below.
- NOTE: Wiring must be done when the AuraSys™ L-4/6 panel power is turned off.
- 4. Configuration
- The module LED flashes red until the panel finishes initialization of Wireless module. After initialization, the wireless module turns the LED on continuously.
- During normal operation, when the module is in programming mode, or any time the module is LOCKED, the LED flashes red.
- The stand alone expansion option cover and back tamper switches prevent vandalism and unauthorized PCB access.
- The module continuously checks the Tampers status when JP5 is disconnected.
- The JP5 jumper is the Tamper jumper. When using the expansion on the board inside the metal casing the tampers must be shorted in order to prevent false alarms.
- When operating as a stand alone module, jumper JP5 must be open (no jumper).
- 5. Limited Warranty
- ROSSLARE ENTERPRISES LIMITED S (Rosslare) TWO YEAR LIMITED WARRANTY is applicable worldwide. This warranty supersedes any other warranty. Rosslare's TWO YEAR LIMITED WARRANTY is subject to the following conditions:
- Warranty
- Warranty of Rosslare's products extends to the original purchaser (Customer) of the Rosslare product and is not transferable.
- Products Covered By This Warranty and Duration
- ROSSLARE ENTERPRISES LTD. AND / ORSUBSIDIARIES (ROSSLARE) warrants that the MatrixBus XR-16A wireless zone expansion, to be free from defects in materials and assembly in the course of normal use and service. The warranty period commences with the date of shipment to the original purchaser and extends for a period of 2 years (24 Months).
- Warranty Remedy Coverage
- In the event of a breach of warranty, ROSSLARE will credit Customer with the price of the Product paid by Customer, provided that the warranty claim is delivered to ROSSLARE by the Customer during the warranty period in accordance with the terms of this warranty. Unless otherwise requested by ROSSLARE ENTERPRISES LTD. AND / OR SUBSIDIARIES representative, return of the failed product(s) is not immediately required.
- If ROSSLARE has not contacted the Customer within a sixty (60) day holding period following the delivery of the warranty claim, Customer will not be required to return the failed product(s). All returned Product(s), as may be requested at ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARY’S sole discretion, shall become the property of ROSSLARE ENTERPRISES LTD. AND /OR SUBSIDIARIES.
- To exercise the warranty, the user must contact Rosslare Enterprises Ltd. to obtain an RMA number after which, the product must be returned to the Manufacturer freight prepaid and insured
- In the event ROSSLARE chooses to perform a product evaluation within the sixty (60) day holding period and no defect is found, a minimum US$ 50.00 or equivalent charge will be applied to each Product for labor required in the evaluation.
- Rosslare will repair or replace, at its discretion, any product that under normal conditions of use and service proves to be defective in material or workmanship. No charge will be applied for labor or parts with respect to defects covered by this warranty, provided that the work is done by Rosslare or a Rosslare authorized service center.
- Exclusions and Limitations
- ROSSLARE shall not be responsible or liable for any damage or loss resulting from the operation or performance of any Product or any systems in which a Product is incorporated. This warranty shall not extend to any ancillary equipment not furnished by ROSSLARE, which is attached to or used in conjunction with a Product, nor to any Product that is used with any ancillary equipment, which is not furnished by ROSSLARE.
- This warranty does not cover expenses incurred in the transportation, freight cost to the repair center, removal or reinstallation of the product, whether or not proven defective.
- Specifically excluded from this warranty are any failures resulting from Customer's improper testing, operation, installation, or damage resulting from use of the Product in other than its normal and customary manner, or any maintenance, modification, alteration, or adjustment or any type of abuse, neglect, accident, misuse, improper operation, normal wear, defects or damage due to lightning or other electrical discharge. This warranty does not cover repair or replacement where normal use has exhausted the life of a part or instrument, or any modification or abuse of, or tampering with, the Product if Product disassembled or repaired in such a manner as to adversely affect performance or prevent adequate inspection and testing to verify any warranty claim.
- ROSSLARE does not warrant the installation, maintenance, or service of the Product. Service life of the product is dependent upon the care it receives and the conditions under which it has to operate. In no event shall Rosslare be liable for incidental or consequential damages.
- Limited Warranty Terms
- this warranty sets forth the full extent of rosslare enterprises ltd. and it’s subsidiaries’s warranty
- the terms of this warranty may not be varied by any person, whether or not purporting to represent or act on behalf of rosslare.
- this limited warranty is provided in lieu of all other warranties. all other warranties expressed or implied, including without limitation, implied warranties of merchantability and fitness for a particular purpose, are specifically excluded.
- in no event shall rosslare be liable for damages in excess of the purchase price of the product, or for any other incidental, consequential or special damages, including but not limited to loss of use, loss of time, commercial loss, inconvenience, and loss of profits, arising out of the installation, use, or inability to use such product, to the fullest extent that any such loss or damage may be disclaimed by law.
- this warranty shall become null and void in the event of a violation of the provisions of this limited warranty.
- 6. Declaration of Conformity
- This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
- 7. Contact information
- 905-912 Wing Fat Industrial Bldg, 12 Wang Tai Road,
- Kowloon Bay Hong Kong
- Tel:+852 2795-5630 Fax: +852 2795-1508
- E-mail: support.apac@rosslaresecurity.com
- 1600 Hart Court, Suite 103 Southlake, TX, USA 76092
- Toll Free:+1-866-632-1101 Local:+1-817-305-0006 Fax: +1-817-305-0069
- E-mail: support.na@rosslaresecurity.com
- HaMelecha 22 Rosh HaAyin, Israel 48091
- Tel: +972 3 938-6838 Fax: +972 3 938-6830
- E-mail: support.eu@rosslaresecurity.com
- Presbitero Actis 555, Oficina 31. San Isidro. Buenos Aires. Argentina
- Tel: +5411-5273-6383 Tel: +305-921-9919
- E-mail: support.la@rosslaresecurity.com
MatrixBus™ XR-16A
Installation Instructions
AuraSys™ L-4/6 Wireless Zone Expansion
1 0706-0960344+01
1. Introduction
This wireless expansion transforms the AuraSys Lite system from a
limited hardwired system into a wireless system. The expansion is a
two way RF communicator which allows connection to wireless
sensors, sirens, keypads, repeaters and remote controls.
With up to 4/6 zones depending on the hosting panel having the
same characteristics as the on board zones.
The stand alone expansion option is housed in a plastic casing
installed outside of the system's case considering RF environment
and wireless devices deployment.
2. Technical Specifications
2.1. Electrical Characteristics
Auxiliary Voltage: 13.4 – 13.8 VDC from hosting panel
Maximum Input Current: 55-75 mA
Indication:
2.2. Environmental Characteristics
Red LED
Operating Environment: indoor use
Operating Temperature: -10°C to 50°C (14°F to 122°F)
Operating Humidity: 0 to 95% (Non-Condensing)
RFI Protection:
2.3. Physical Characteristics (with case)
>20 V/m up to 1000 MHz.
Dimensions (HxWxD): 101 x 99 x 35 mm (4 x 3.9 x1.4 in)
Weight:
2.4. Available models:
143 g (0.316 lbs)
XR-16AH – 868.35 MHz
XR-16AG – 433.92 MHz
3. Installation
3.1. General
The XR-16A is designed for easy installation. Only a few steps are
required to install the keypad.
Changes or modifications to this equipment not expressly
approved by Rosslare security as the party responsible for
compliance could void the user’s authority to operate the
equipment.
3.2. Mounting the XR-16A expansion
Perform the following steps to mount the expansion:
1) Remove the four screws holding the front cover. Set the
screws aside.
2) Disassemble the PCB assembly from the back plate, remove
the four screws holding the PCB, set them aside.
3) Locate the back plate at the desired installation location.
The wireless expansion should be installed at a secured
location considering RF environment and wireless devices
deployment.
4) Use the back cover itself as a template for the wall screws.
5) Drill holes in the wall and insert anchors. Hardware is
provided.
6) Route a four-wire cable from the panel to the wireless
expansion location.
7) Pass the 4-wire cable via one of the channels designed in
the back plate. Use pliers to remove the section covering
the channel.
8) Mount and fasten the back plate using the screws provided.
Make sure to level the plate.
9) Make wiring connections, to the PCB assembly and mount
on the back plate.
10) Secure with the screws, set aside previously.
3.3. Wiring
Refer to the wiring diagram below.
NOTE: Wiring must be done when the AuraSys™ L-4/6 panel
power is turned off.
4. Configuration
4.1. LEDs
The module LED flashes red until the panel finishes initialization of
Wireless module. After initialization, the wireless module turns the
LED on continuously.
During normal operation, when the module is in programming
mode, or any time the module is LOCKED, the LED flashes red.
4.2. Tamper
The stand alone expansion option cover and back tamper
switches prevent vandalism and unauthorized PCB access.
The module continuously checks the Tampers status when JP5 is
disconnected.
The JP5 jumper is the Tamper jumper. When using the expansion
on the board inside the metal casing the tampers must be
shorted in order to prevent false alarms.
When operating as a stand alone module, jumper JP5 must be
open (no jumper).
MatrixBUS